Advanced WP7-90-27-300 / US UNIT / US VOLTAGE !
Produktnummer:
Used US 200445 only US
Produktinformationen "Advanced WP7-90-27-300 / US UNIT / US VOLTAGE !"
Advanced WP7-90-27-300 SN 200445
Temperature up to: 90 °C / 194 °F
Heating capacity: 27 kW
Cooling capacity: 300 kW
Circulating medium: Water up to 90°C
Flow rate: max. 230l/min
Max. pressure: max. 2,3 bar
Motor capacity: 0,75 kW
Voltage: USA
Stock location: Single USA
Serial Nuber : 200445
Typ : Used Unit
Hydraulic functional equipment
· Cooling and filling controlled by solenoid valve· Configurable automatical filling via cooling water or separate connection (ex works cooling water inlet)
· Flow measurement by differential pressure
· Level monitoring by magnetic float switch
· Automatic temperature-dependent system closing (not for 90°C)
· Flow monitoring by recording surface temperature of heating rods and flow
· Bypass between to and from process with reduced cross-section
· Dirt trap in cooling water supply, filling connection and return line of circulating system
· Continuous bypass of heat exchanger by 3-way-motorvalve (WP7-180/200)
· System pressure monitoring by pressure transmitter in extension vessel (WP7-150/180/200)
· Booster pump for filling (WP7-180/200, 150° optional)
· Saftey temp. limiter (STB) in heating and to process line (WP7-200)
· Manometer in to process line at backside of unit
· Medium circuit insulated (WP7-150/180/200)
Functional equipment electrical
· Smart Controller (7" touch display)
· Heating control by solid-state-relay
· Control cabinet IP54
General equipment
· Expansion vessel, heater and piping made of stainless steel· Heating with Incolloy stainless steel tubular heaters
· Dirt trap (medium): EN-GJL-250; GP240GH+N
· Unit ready for connection and mounted on castors, thereof 2 swivel castors with brakes
Special equipment
· Special voltage 440-480V +/-5% / 60Hz 3p
· Pipe connection for filling WK3 with ball valve· Special setting in the unit: - for manual filling
· Air inlet valve (Art.No.06653) in the manual filling line, after ball valve Overflow valve for WP7 between to and from process up to 150° discharge pressure: * 1,5 bar for units with flow measunring: the total flow rate of the device will be displayed. (overflow valve will be mounted before flow measuring)
Professional package:
· Smart Controller plus
· Prequency converter· Pressure transducer
· If a fault-current circuit breaker (FI) is installed in the electrical supply line to the TCU, a FI "Type B" must be used.
· If the rated current of the FI is 30mA only one TCU can be operated at this FI
· Alarm status Alarms and Warnings by potential-free contact on clamp on I/O-board incl. warning for delta T (pre- and return run) and return run temperature (- no charge)
· Special connections for Medium, cooling water and filling
Die Abbildungen und Zeichnungen, Größen-, Gewichts-, Verbrauchs-, Leistungsangaben sowie chemischen und physikalischen Angaben sind stets annähernd.