WP4S-150-18-120 SN250344

These options are currently not available.

Temperature range up to C°
Heating capacity in kW
Cooling capacity in kW
Max. flow rate in l/min
Max. pressure in bar
Product number: SN 250344
Product information "WP4S-150-18-120 SN250344"

IM150B

 

Temperature up to: 150 °C

Heating capacity: 18 kW

Cooling capacity: 120 kW

Maximum flow rate: 73 l/min

Maximum pressure: 7.5 bar

 

 

Functional equipment hydraulic:

- Bypass between to and from process with reduced crosssection

- Level monitoring by magnetic float switch

- Manometer in to process line at backside of unit

- Flow measurement by differential pressure

- Flow monitoring by recording flow

- Dirt trap in cooling water supply and return line of circulating system

- Medium circuit insulated

 

Functional equipment electrical:

- Smart Controller Plus (7" touch display)

- Heating controlled via SSR

- Control cabinet IP54 forced ventilation

 

General equipment:

- Expansion vessel, heater and piping made of stainless steel

- Heating with Incolloy stainless steel tubular heaters

- Dirt trap (medium): 1.4408

 

Selected features:

- Pressure gauge in pre run (M.PG1.WP4S)

- Professional package (PRO.WP4S)

consisting of:

Smart Controller plus, frequency converter and

pressure transducer

If a fault-current circuit breaker (FI) is

installed in the electrical supply line

to the TCU, a FI "Type B" must be used.

If the rated current of the FI is 30mA

only one TCU can be operated at this FI

- Tool drainage by compressed air (M.TDA.WP4S)

with non-return valve, solenoid valve, fitting

for compressed air, impulse via

control unit/ overflow to

cooling water + pressure release

Connection: Hose nipple 10 mm

- Current interface 20mA Arburg (SSC.IFARBURG)

via 9-pin D-sub connector

- Euromap 82.1 based on OPC UA, connection RJ45 (SSC.IFOPC)

- electrical preparation for SFC at TCU WP4S (SFC.R2.WP4S)

- plug 32 A/ CEE completely installed (E.PSC32.WP4S)

- Connection for external temperature sensor: PT 100 (SSC.EXTSPT3)

2-conductor or 3-conductor

 

 

 

The illustrations and drawings, size, weight, consumption, performance, chemical and physical data are always approximate.